- A -
Actions
Save recognized partition layout
Set raw file search options...
APFS Fusion Drive Components tab
Apple CoreStorage/File Vault/Fusion Drive Volumes
- B -
Bad Sectors settings
Broken File Name options
Buttons
Change Raw File Search Options
- C -
Connect to Restorer settings
Allow connection from any address
Allow connection from the host
Contact Informaiton and Technical Support
Create a Virtual Volume Set or RAID
- D -
Data Recovery from Volume Sets and RAIDs
Data Recovery on HFS/HFS+ File System
Description Files for RAID Configuration
Dialog boxes
There is not enough process memory...
- E -
Edit menu
- F -
File mask options
File menu
File Recovery on a Remote Computer
File Systems settings
Default encoding for Ext2/Ext3/Ext4/UFS volumes
Default encoding for HFS volumes
Find options
Finding Previous File Versions
- H -
Help menu
- I -
Image options
Introduction to Restorer Ultimate
- L -
Log settings
- M -
Main settings
Disable All Warnings and Confirmations
Show All Warnings and Confirmations
Memory Usage settings
- N -
Nested and Non-Standard RAID Levels
- O -
Options
- P -
Panels
Panes
- Q -
- R -
RAID 6 Presets
RAID options
Recover Files from Deleted/Corrupted Logical Disks and Partitions
Recover Files from Existing Logical Disks
Recover options
Do not recover hidden and system attributes
Recover all content of a selected folder, ignoring specified file mask:
Recover alternative data streams:
Recover real folders structure
Recover the entire path to the file object:
Region options
Restorer Ultimate Remote Emergency Engine
Restorer Ultimate Remote Engine
Restorer Ultimate Remote Engine Options
- S -
Scan options
Search options
Settings
Delete Recognized Partition Layout
Find Previous Versions of the File
Open Recognized Partition Layout
Save Recognized Partition Layout
Show Files Sorted by
Syntaxis of a Description File for RAID Configurations
- T -
Task List
- V -
View menu
Volume Sets, Stripe Sets, and Mirrors
- W -
Window
(Available on Restorer Ultimate PRO and Restorer Ultimate PRO Network only).
To create a Spanned volume object
1 | Click Create Virtual RAID on the Task List |
> | A Create Virtual RAID wizard will appear to guide you through the process of creating the Virtual Spanned Volume. |
2 | Select Virtual Spanned Volume on the Create Virtual RAID dialog box then click the Next button |
3 | Select the required objects on the Available disks list, add them to the Selected disks list, and click the Finish button |
Available disks |
List of disks available for creating virtual disk arrays |
Show Partitions |
If this check box is selected, Restorer Ultimate also shows partitions on hard drives |
Show as: |
Select the units in which you want to see object sizes. You may select, Bytes , Sectors , and Bytes and Sectors . |
Selected disks |
List of disks selected for creating virtual disk arrays |
Buttons |
|
Add |
Click this button to add the selected disk from the Available disks list to the Selected disks list |
Remove |
Click this button to remove the selected disk from the Selected disks list |
Remove All |
Click this button to remove all selected disks from the Selected disks list |
Move Up |
Click this button to move the selected disk one level up in the Selected disks list |
Move Down |
Click this button to move the selected disk one level down in the Selected disks list |
Add Missing Disk |
Click this button to add a virtual disk into virtual disk array that will be created |
Note: Components should be placed in the same order and the offsets should be specified as they were in the original volume set. If this order is incorrect, you must change it by using the Move Up and Move Down buttons.
If a component from the objects is absent (due to hardware failure, for example), you can add a "missing disk" to re-construct the RAID. The missing disk should be placed in the same order as in the original RAID structure.
> | A Virtual volume object will appear on the Device/Disk list panel |
The Virtual volume set or RAIDs object can now be processed like regular drives/volumes.
If Restorer Ultimate detects a valid file system on the newly created RAID object, a partition object will appear on the Device/Disk list panel.
To create a Stripe set object (RAID 0)
1 | Click Create Virtual RAID on the Task List |
> | A Create Virtual RAID wizard will appear to guide you through the process of creating a Virtual Stripe set (RAID 0). |
2 | Select Virtual Block RAID on the Create Virtual RAID dialog box then click the Next button |
3 | Select the required objects on the Available disks list, add them to the Selected disks list, and click the Finish button |
Available disks |
List of disks available for creating virtual disk arrays |
Show Partitions |
If this check box is selected, Restorer Ultimate also shows partitions on hard drives |
Show as: |
Select the units in which you want to see object sizes. You may select, Bytes , Sectors , and Bytes and Sectors . |
Selected disks |
List of disks selected for creating virtual disk arrays |
Buttons |
|
Add |
Click this button to add the selected disk from the Available disks list to the Selected disks list |
Remove |
Click this button to remove the selected disk from the Selected disks list |
Remove All |
Click this button to remove all selected disks from the Selected disks list |
Move Up |
Click this button to move the selected disk one level up in the Selected disks list |
Move Down |
Click this button to move the selected disk one level down in the Selected disks list |
Add Missing Disk |
Click this button to add a virtual disk into virtual disk array that will be created |
Note: Components should be placed in the same order and the offsets should be specified as they were in the original volume set. If this order is incorrect, you must change it by using the Move Up and Move Down buttons.
If a component from the objects is absent (due to hardware failure, for example), you can add a "missing disk" to re-construct the RAID. The missing disk should be placed in the same order as in the original RAID structure.
You may turn the objects in the virtual RAID0 on-line and off-line by selecting/clearing the On checkbox on the Create Virtual RAID dialog box .
Actually, when you turn an object off-line, Restorer Ultimate substitutes it with a Missing Disk or Empty Space object.
4 | Click the Next button and select the other parameters for your RAID0 and click the Finish button |
Select RAID0(Stripe set) in RAID type .
The RAID block size parameter must be set the same as for the original volume set.
If those parameters are not correct, data on the parents will not be damaged, but the data from the RAID0 cannot be recovered.
> | A Virtual block RAID object will appear on the Device/Disk list panel |
The Virtual block RAID object can now be processed like regular drives/volumes.
If Restorer Ultimate detects a valid file system on the newly created RAID object, a partition object will appear on the Device/Disk list panel.
Note: You may check how correctly you have reconstructed the RAID0. Find a file and preview it. If the file appears correct, you have created a correct RAID layout. The file should be large enough. For example, it should have size equal or larger to Block size*Number of disks for RAID0.
To create a Mirror set object (RAID 1)
> | A Create Virtual RAID wizard will appear to guide you through the process of creating a Virtual Mirrot set (RAID 1). |
2 | Select Virtual Mirrored Volume on the Create Virtual RAID dialog box then click the Next button |
3 | Select the required objects on the Available disks list, add them to the Selected disks list, and click the Finish button |
Available disks |
List of disks available for creating virtual disk arrays |
Show Partitions |
If this check box is selected, Restorer Ultimate also shows partitions on hard drives |
Show as: |
Select the units in which you want to see object sizes. You may select, Bytes , Sectors , and Bytes and Sectors . |
Selected disks |
List of disks selected for creating virtual disk arrays |
Buttons |
|
Add |
Click this button to add the selected disk from the Available disks list to the Selected disks list |
Remove |
Click this button to remove the selected disk from the Selected disks list |
Remove All |
Click this button to remove all selected disks from the Selected disks list |
Move Up |
Click this button to move the selected disk one level up in the Selected disks list |
Move Down |
Click this button to move the selected disk one level down in the Selected disks list |
Add Missing Disk |
Click this button to add a virtual disk into virtual disk array that will be created |
Note: Components should be placed in the same order and the offsets should be specified as they were in the original volume set. If this order is incorrect, you must change it by using the Move Up and Move Down buttons.
If a component from the objects is absent (due to hardware failure, for example), you can add a "missing disk" to re-construct the RAID. The missing disk should be placed in the same order as in the original RAID structure.
> | A Virtual mirror object will appear on the Device/Disk list panel |
The Virtual mirror object can now be processed like regular drives/volumes.
If Restorer Ultimate detects a valid file system on the newly created RAID object, a partition object will appear on the Device/Disk list panel.
Note: You may check how correctly you have reconstructed the RAID 1. Find a file and preview it. If the file appears correct, you have created a correct RAID layout.